TM 1-1520-238-23
11-165
11.31.
COLLECTIVE STICK BORESIGHT SWITCH REPLACEMENT continued
11.31.5. Inspection
a. Check for cracked and broken wires. None al-
lowed.
b. Check removed and attaching parts for
cracks. None allowed.
c. Check removed and attaching parts for dam-
age (para 11.5).
d. Check removed and attaching parts for corro-
sion (para 1.49).
11.31.6. Installation
a. Install switch (10) on plate (8).
(1) Position switch (10) on plate (8).
(2) Install keywasher (14), lockwasher (13), and
nut (12).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
b. Solder wires (11) to switch (10).
(1) Solder identified wires (11) to switch (10).
Use soldering iron and solder (item 189,
App F) (TM 55-1500-323-24).
c. Apply a thin coat of adhesive over switch (10)
solder joint and bare wires (11). Use adhesive
(item 14, App F).
GO TO NEXT PAGE
M04-3516-4
8
11
10
14
12
13