TM 1-1520-238-23
11-227
11.47.
PILOT CYCLIC STICK TRIM AND FORCE FEEL RELEASE SWITCH REPLACEMENT continued
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
d. Desolder wires (6) from switch (4).
(1) Identify and desolder wires (6) from switch
(4). Use soldering iron (TM 55-1500-323-24).
11.47.4. Cleaning
a. Clean adhesive from removed and attaching
parts (para 1.47).
11.47.5. Inspection
a. Check wires for cracks or broken insulation.
None allowed.
b. Check removed and attaching parts for
cracks. None allowed.
c. Check removed and attaching parts for dam-
age. None allowed.
d. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
ROTATED FOR CLARITY
6
4
M04-3518-2