TM 1-1520-238-23
11-884
11.203.
CPG COLLECTIVE CONTROL POSITION LINEAR VARIABLE DIFFERENTIAL TRANSDUCER
(LVDT) REMOVAL
11.203.1. Description
This task covers:
Removal. Cleaning. Inspection.
11.203.2. Initial Setup
Tools:
Aircraft mechanics tool kit (item 376, App H)
Personnel Required:
67R
Attack Helicopter Repairer
References:
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
11.44
Collective stick cover removed
11.203.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot center circuit breaker panel, open
ASE AC, DC, and BUCS circuit breakers.
GO TO NEXT PAGE
CPG STATION
M04-1857-1