PRIMARY AND RESERVE FIRE EXTINGUISHER INSTALLATION - continued
f. Install tube (13) on two-way check valve (14).
(1) Hold check valve (14). Use open end wrench.
(2) Install nut (15). Use crowfoot.
g. Install tube (13) on swivel (16).
(1) Hold swivel (16). Use adjustable wrench.
(2) Install nut (17). Use crowfoot.
h. Install tube (18) on two-way check valve (19).
(1) Hold check valve (19). Use open end wrench.
(2) Install nut (20). Use open end wrench.
i. Install tube (18) on swivel (21).
(1) Hold swivel (21). Use adjustable wrench.
(2) Install nut (22). Use crowfoot.