TM 1-1520-238-23
Change 1
12-157
12.50.
PILOT ANTI-ICE PANEL RECEPTACLE REPLACEMENT - continued
f. Remove three posts (8) from panel (12).
(1) Remove three screws (13) from posts (8).
(2) Remove posts (8).
12.50.4. Cleaning
a. Clean sealing compound from removed parts
(para 1.47).
b. Wipe removed and attaching parts with a
clean rag.
12.50.5. Inspection
a. Check wires for cuts, nicks, fraying, or chaf-
ing (para 12.46).
b. Check removed and attaching parts for corro-
sion (para 1.49).
c. Check removed and attaching parts for cracks
(TM 1-1500-204-23).
12.50.6. Installation
NOTE
If connector bracket or posts were re-
moved, go to step a. If bracket and posts
were not removed, go to step d.
a. Install three posts (8) on panel (12).
(1) Apply sealing compound on three screws
(13). Use sealing compound (item 169,
App F).
(2) Install three screws (13) through panel (12)
into posts (8).
GO TO NEXT PAGE
M04-1839-4A
12
13
13
13
8
8