TM 1-1520-238-23
12-295
12.68.
WINDSHIELD ANTI-ICE TEMPERATURE CONTROL BOX CIRCUIT CARD ASSEMBLY (CCA)
REMOVAL/INSTALLATION (AVIM) - continued
WARNING
Soldering gun can cause severe burns
to personnel and start fires. Observe
all safety precautions when using
soldering gun. If injury occurs, seek
medical aid.
b. Identify and desolder wires (7) from CCA A1
(1)
or
A2
(2).
Use
soldering
gun
(TM 55-1500-323-24).
c. Remove and discard CCA A1 (1) or A2 (2).
12.68.4. Cleaning
a. Clean removed and attaching parts (para
1.47).
12.68.5. Inspection
a. Check removed and attaching parts for dam-
age (para 12.46).
GO TO NEXT PAGE
7
7
2
1
M04-3778-3