TM 1-1520-238-23
13-36
Change 3
13.11.
ENCU TEMPERATURE CONTROL SENSOR REMOVAL/INSTALLATION - continued
13.11.5. Inspection
a. Check air duct for cracks (para 13.1).
b. Check duct nutplates for loose rivets and
stripped or damaged threads (para 13.1).
c. Check removed and attaching parts for corro-
sion (para 1.49).
d. Check sensor for loose, missing or damaged
hardware. None allowed.
e. Check sensor for damage, overheating, and
paint damage. None allowed.
f. Check sensor identification plate (para 13.1).
g. Check sensor receptacle for cracks corro-
sion, and broken, bent, or damaged pins
(TM 55-1500-323-24).
13.11.6. Installation
a. Install sensor (3) on air duct (4).
(1) Position sensor (3) and new gasket (7) on
duct (4).
(2) Install three screws (5) and washers (6).
b. Attach connector P285 (1) to receptacle
(A43)J1 (2).
c. Apply sealing compound to edges of sensor
(3), screws (5), washers (6), and around edge
of connector P285 (1). Use sealing compound
(item 176, App F).
d. Inspect (QA).
e. Perform ECS maintenance operational check
(TM 1-1520-238-T).
f. Secure access doors T250L, T250R, T290L,
T290R, and L325 (para 2.2).
END OF TASK
M04-3007-3A
3
5
1
2
7
4
6