ENCU WATER EXTRACTOR ASSEMBLY REPLACEMENT - continued
13.10.3. Removal
a. Remove hose (1) from water extractor assem-
bly (2).
(1) Loosen clamp (3) from hose (1).
(2) Remove hose (1) and clamp (3).
b. Remove hose (4) from elbow (5).
(1) Loosen clamp (6) from hose (4).
(2) Remove hose (4) and clamp (6).
c. Remove extractor (2) from hoses (7) and (8).
(1) Loosen two clamps (9) and (10) from hoses
(7) and (8).
(2) Remove extractor (2) and clamps (9) and
(10).
d. Remove elbow (5) from extractor (2).
(1) Loosen nut (11).
(2) Remove and retain elbow (5).
(3) Remove and discard packing (12).
13.10.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
13.10.5. Inspection
a. Check ENCU ducts, hoses, and clamps for
chafing, cracks, or wear (para 13.1).
b. Check removed and attaching parts for corro-
sion (para 1.49).
c. Check extractor for cracks, punctures, and
broken welds. None allowed.
d. Check extractor swirl vanes for broken or
cracked welds. None allowed.
e. Check extractor for minor dents, nicks,
scratches and bent ducts. Repair minor surface
damage (TM 1-1500-204-23).