TM 1-1520-238-23
15-135
15.36.
APU FORWARD LEFT OR RIGHT MOUNT FITTING REPLACEMENT - continued
15.36.3. Removal
a. Remove left or right mount fitting (1).
(1) Remove lockwire from two bolts (2).
(2) Remove two bolts (2), washers (3), and fitting
(1) from APU (4).
15.36.4. Cleaning
a. Clean removed and attaching parts and sur-
faces (para 1.47).
15.36.5. Inspection
a. Check APU aft support strut and truss assem-
blies for cracks, dents, and scratches (para
15.1).
b. Check aft strut mount rod end for wear
(TM 55-1500-322-24).
c. Check APU exhaust nozzle for cracks or heat
discoloration (para 15.1).
d. Check removed and attaching parts and sur-
faces for corrosion (para 1.49).
15.36.6. Installation
a. Install left or right fitting (1).
(1) Install two bolts (2) through washers (3) and
fitting (1) into APU (4).
b. Lockwire two bolts (2) together. Use wire
(item 226, App F).
c. Inspect (QA).
d. Install APU (para 15.3).
e. Remove maintenance crane (para 1.105).
END OF TASK
M04-3752-2
1
M04-3752-3
1
M04-3752-4
4
3
2
1
M04-3752-5
4
1
3
2