TM 1-1520-238-23
16-137/(16-138 blank)
16.36.
APU AIR FILTER REPLACEMENT - continued
16.36.6. Installation
CAUTION
During installation, care must be taken to
prevent tearing, crushing, or stretching
filter material.
a. Install filter (1) on APU inlet screen (2) with
white side out.
(1) Wrap filter (1) around inlet screen (2) with
white side out (push filter away from inlet
screen flanges to prevent hang-up on bolts
and safety wire).
(2) Secure velcro strips (3) together.
b. Install APU upper center cover (para 15.42).
END OF TASK
WHITE SIDE
3
1
3
2
M04-3769-3
1
2
3
APU INLET
M04-3769-4