PROCEDURE
TROUBLESHOOTING
REFERENCE
AFTER STARTING APU (CONT)
(d) Note HSI and RMI bearing
indications are within 5
of station bearing (if
known).
NOTE
Direction of rotation during TEST and with
switch released is indicative of signal
strength and shortest distance to rotate, re-
spectively.
(e) CW-VOICE-TEST switch
TEST. Note HSI and RMI
bearing indicators rotate
180 5.
(f) CW-VOICE-TEST switch
CW or VOICE as
appropriate. Note bearing
pointers return to previously
noted bearing 5.
(3) LOOP mode operation:
(a) Mode selector LOOP.
NOTE
Audio tone should increase and decrease
approximately each 90 from originally
noted bearing.
(b) LOOP L-R control Adjust
to obtain null. Adjust to
obtain the opposite null
approximately 180 from
original bearing.