TM 1-1520-238-MTF
2-57
Change 3
PROCEDURE
TROUBLESHOOTING
REFERENCE
STARTING ENGINES PILOT (CONT)
CAUTION
The T700GE701C engine exhibits in-
consistent starting capability above
6000 feet density altitude. Starts above
this density altitude may be unsuccess-
ful and require over temperature abort
by the pilot.
2. Area Clear.
3. Fire guard Posted, if available.
4. ENG 1 and ENG 2 FUEL switches
Verify ON.
WARNING
Main rotor brake could fail. Maintenance
personnel will remain clear of all drive
train components until completion of
ground run.
5. RTR BK switch As desired.
6. ANTI-ICE panel ENG INLET switch
Verify OFF.
7. EXT LT As required.
8. ANTI COL light As required.
*9. First engine Start as follows:
a. Verify ENG 1 and ENG 2 inlet
advisory lights are illuminated.
A4, G