TM 1-1520-238-PM
280
C1
PHASE NO.
Date
Aircraft Serial No.
Area Name and No.
AFT EQUIPMENT BAY 11
Inspect
Phase
Nos.
Initial
Action Taken
Faults and/or Remarks
Status
Inspection Requirements
2,4
13.
FIRE EXTINGUISHER CONTAINERS FOR
DENTS AND MOUNTING SECURITY.
C
CARTRIDGES, FITTINGS, AND VALVES
FOR CRACKS, DISTORTION, AND
SECURITY. CHECK CONTAINER
CHARGE PRESSURE AND WEIGHT.
INSPECT DISCHARGE INDICATING DISK.
INSPECT THE SYSTEM CHECK VALVES
FOR INTERIOR CORROSION, PITTING,
AND EVIDENCE OF EVAPORATION.
Access L325, T250L, T290L, T250R,
T290R
ALL
14.
Fire extinguisher outlet tubing and
fittings for cracks, dents, nicks, wear,
C
chaffing, fire bottle outlet ports,
distortion, security and corrosion.
Interior of tubes around B nut area for
corrosion
Access L325, T250L, T290L, T250R,
T290R
ALL
14a. Fire extinguisher check valves for pitting,
corrosion, evaporation residue, or cracking.
FOD REMINDER
Check work area for tools and parts after completion of maintenance and inspection.