FOD REMINDER
Check work area for tools and parts after completion of maintenance and inspection
TM 1-1520-238-PMS
C 5
23
Seq.
No.
Location
Item and Procedure
2.12
37
WING
CRACKS, DISTORTION, CORROSION, AND MOUNTING SECURITY
LOOSE OR MISSING HARDWARE
38
ANTICOLLISION LIGHT LENS FOR CRACKS AND MOUNTING SECURITY
39
NAVIGATION LIGHT LENS FOR CRACKS AND MOUNTING SECURITY
40
FORMATION LIGHT LENS FOR CRACKS AND MOUNTING SECURITY
41
STATIC DISCHARGERS FOR EXPOSED WICK
42
PITOT TUBE FOR OBSTRUCTIONS, CLEANLINESS, AND DAMAGE
43
PITOT DRAIN EXTERNAL FITTING FOR OBSTRUCTION AND DAMAGE
DRAIN AND CHECK FOR MOISTURE
44
Intercommunication connector cap installed
2.13
45
PYLONS (EXTERNAL STORES)
NOTE
Use 10-power magnifying lens to check yoke and rack in pivot pin area.
CRACKS, DISTORTION, AND MOUNTING SECURITY
Visible wiring for chafing or damaged insulation and connection security
Hydraulic lines for leakage, chafing, and security
SAFETY PINS AND STREAMERS INSTALLED
IF STORES NOT MOUNTED, CHECK UMBILICAL STOWAGE INSIDE PYLON LEADING EDGE FAIRING
CAUTION
When handling sensor unit, do not press on sensor window. The glass is fragile and may be scratched,
cracked, or broken.
2.14
46
Laser Detecting Sensor (forward) Right Side
Physical damage and mounting security
Clean oil, dust, or other deposits from sensor window (TM 11-5841-304-12)