TM 11520238T1
Change 4
431
44
AWS INTERACTIVE FD/LS CHECK (cont)
44
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
GUN TURRET
CONTROL BOX
NOGO RH FAB
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2). If
troubleshooting does not
remove NOGO, replace gun
turret control box
(TM 9-1090-208-23-1).
RNDS CNTRMAG
CONTROLLER
NOGO AFT OF LH
FAB (ACY) OR
RNDS CNTRMAG
CONT NOGO AFT OF
LH FAB (ACZ)
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2). If
troubleshooting does not
remove NOGO, replace
rounds counter
(TM 9-1090-208-23-1).
TRAIN RATE SENSOR
NOGO GUN TURRET
ASSY
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2). If
troubleshooting does not
remove NOGO, replace
train rate sensor
(TM 9-1090-208-23-1).
GUN CONTROL BOX
NOGO RH FAB
Troubleshoot wiring to isolate
fault (TM 9-1090-208-23-2). If
troubleshooting does not
remove NOGO, replace gun
control box
(TM 9-1090-208-23-1).
GUN BORESIGHT
NOGO RAM
CHECKSUM
Refer to TM 9-1230-476-20-1
for boresight editing and
insert correctors from the
aircraft logbook. If FCC
battery is suspect, refer to
TM 9-1230-476-20-2 . (ACY)
END OF TASK