TM 11520238T3
Change 4
59
524 SIGNAL NAME:
ORT WPN TRIG DET 1 TO TEU (ACY) ORT TRIG 1ST TST (ACZ)
MEMORY LOCATION: 001252
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates CPG has pulled ORT weapon trigger to first detent. This test
performed during TADS FD/LS maintenance test, on ground only, to allow TEU
to test ORT switches.
REMARKS: From FCC through LH FAB MRTU Type I to TEU.
PASS:
If second digit displayed on HOD is 0, 1, 2 or 3, go to paragraph 525.
FAIL: Location of fault: LH FAB MRTU Type I, wiring from LH FAB MRTU Type I to TEU, TEU.
Troubleshoot wiring to isolate fault (TM 91090208232).
525 SIGNAL NAME:
ORT WPN TRIG DET 2 TO TEU (ACY) ORT TRIG 1ST TST (ACZ)
MEMORY LOCATION: 001252
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates CPG has pulled ORT weapon trigger to second detent. This test
performed during TADS FD/LS maintenance test, on ground only, to allow TEU
to test ORT switches.
REMARKS: From FCC through LH FAB MRTU Type I to TEU.
PASS:
If second digit displayed on HOD is 0, 1, 4, or 5, go to paragraph 526.
FAIL: Location of fault: LH FAB MRTU Type I, wiring from LH FAB MRTU Type I to TEU, TEU.
Troubleshoot wiring to isolate fault (TM 11270476T).
526 SIGNAL NAME:
ORT GUN WAS TO TEU (ACY) ORT GUN WAS TST (ACZ)
MEMORY LOCATION: 001252
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Issues ORT gun weapon action switch (WAS) signal to TEU. This test
performed during TADS FD/LS maintenance test, on ground only, to allow TEU
to test ORT switches.
REMARKS: From FCC through LH FAB MRTU Type I to TEU.
PASS:
If first digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 527.
FAIL: Location of fault: LH FAB MRTU Type I, wiring from LH FAB MRTU Type I to TEU, TEU.
Troubleshoot wiring to isolate fault (TM 91230476202).
527 SIGNAL NAME:
PLT HAS GUN
MEMORY LOCATION: 001530
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates pilot has control of gun.
REMARKS: From GTCB through RH FAB MRTU Type I to FCC.
PASS:
If second digit displayed on HOD is 2, 3, 6, or 7, go to paragraph 528.
FAIL: Location of fault: CPG FCP, wiring from CPG FCP to GTCB, GTCB, wiring from GTCB to RH
FAB MRTU Type I, RH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91090208232).