64 SIGNAL NAME:
HARS INTERNAL TEST REPLY (ACY) HARS TEST PERF (ACZ)
MEMORY LOCATION: 002154
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates HARS completed internal test.
REMARKS: From HARS through DASEC to FCC.
PASS:
If second digit on HOD is 1, 3, 5, or 7, go to paragraph 65.
FAIL: Location of fault: HARS, wiring from HARS to DASEC, DASEC. Troubleshoot wiring to isolate
fault (TM 111520238232).