TM 11520238T3
Change 4
67
623 SIGNAL NAME:
HARS NORTH
MEMORY LOCATION: 002202
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
When in bobup mode, HARS integraters are reset. HARS begins to indicate drift in +
(North) and (South) based on velocity computed from integrating accelerometer
outputs.
SIGNAL FUNCTION:
Indicates north movement when in bobup mode.
REMARKS: From HARS through DASEC to FCC.
PASS:
If conditions are met go to paragraph 624.
FAIL: Location of fault: DEK, wiring from DEK to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 91230476202).
624 SIGNAL NAME:
HARS EAST
MEMORY LOCATION: 002203
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
When in bobup mode, HARS integraters are reset. HARS begins to indicate drift in
+(East) and (West) based on velocity computed from integrating accelerometer
outputs.
SIGNAL FUNCTION:
Indicates east movement when in bobup mode.
REMARKS: From HARS through DASEC to FCC.
PASS:
If conditions are met go to paragraph 625.
FAIL: Location of fault: DEK, wiring from DEK to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 91230476202).
625 SIGNAL NAME:
MAGVAR TO HARS (ACY) MAGVAR AID (ACZ)
MEMORY LOCATION: 002232
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor HOD; MAGVAR positive equals 0 to 180 DEG and MAGVAR negative equals
180 to 360 DEG.
SIGNAL FUNCTION:
Determines position of magnetic variation.
REMARKS: From FCC through DASEC to HARS.
PASS:
If conditions are met go to paragraph 626.
FAIL: Location of fault: DEK, wiring from DEK to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 91230476202).
626 SIGNAL NAME:
USE MAGHDG CTL (ACY) MAGVAR AID VALID (ACZ)
MEMORY LOCATION: 002235
MEMORY DATA BIT(S):
6
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Instructs HARS to use the MAGHDG input when in the inflight align mode.
REMARKS: From FCC through DASEC to HARS.
PASS:
If fifth digit on HOD is 2, 3, 6, or 7, go to paragraph 627.
FAIL: Location of fault: DEK, wiring from DEK to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 91230476202).