TM 11520238T3
Change 4
69
631 SIGNAL NAME:
HARS COS MAGHDG
MEMORY LOCATION: 002161
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor HOD; HARS COS MAGHDG positive increases from West to East (HARS SIN
MAGHDG negative decreases from East to West).
SIGNAL FUNCTION:
Monitors HARS cosine of magnetic heading with respect to the navigational
heading.
REMARKS: From HARS through DASEC to FCC.
PASS:
Location of fault if conditions are met, go to Chapter 20, paragraph 2080.
FAIL: Location of fault: HARS, wiring from HARS to DASEC, DASEC. Troubleshoot wiring to isolate
fault (TM 111520238232).
632 SIGNAL NAME:
HARS LAT
MEMORY LOCATION: 002151
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor HOD; HARS LAT positive equals left movement (HARS LAT negative equals
right movement).
SIGNAL FUNCTION:
Most significant 16 bits of HARS latitude estimate.
REMARKS: From HARS through DASEC to FCC.
PASS:
If conditions are met, go to paragraph 633.
FAIL: Location of fault: HARS, wiring from HARS to DASEC, DASEC. Troubleshoot wiring to isolate
fault (TM 111520238232).
633 SIGNAL NAME:
HARS LAT L (ACY) HARS LAT LSBS (ACZ)
MEMORY LOCATION: 002153
MEMORY DATA BIT(S):
411
(SCALAR)
CONDITION:
Monitor HOD; HARS LAT L positive equals left movement (HARS LAT L negative
equals right movement).
SIGNAL FUNCTION:
Least significant 8 bits of HARS latitude estimate.
REMARKS: From HARS through DASEC to FCC.
PASS:
If conditions are met, go to paragraph 634.
FAIL: Location of fault: HARS, wiring from HARS to DASEC, DASEC. Troubleshoot wiring to isolate
fault (TM 111520238232).
634 SIGNAL NAME:
HARS LONG
MEMORY LOCATION: 002152
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor HOD; HARS LONG positive equals forward movement (HARS LONG negative
equals aft movement).
SIGNAL FUNCTION:
Most significant 16 bits of HARS longitude estimate.
REMARKS: From HARS through DASEC to FCC.
PASS:
If conditions are met, go to paragraph 635.
FAIL: Location of fault: HARS, wiring from HARS to DASEC, DASEC. Troubleshoot wiring to isolate
fault (TM 111520238232).