TM 11520238T3
Change 4
79
729 SIGNAL NAME:
BRT TO PLT DAP (ACY) PLT IHAD BRT CMD (ACZ)
MEMORY LOCATION: 001606
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor HOD while adjusting pilot DAP brightness from minimum () to maximum (+).
SIGNAL FUNCTION:
Controls IHADSS brightness.
REMARKS: From FCC through RH FAB MRTU Type I to pilot DAP.
PASS:
If condition is met go to paragraph 730.
FAIL: Location of fault: RH FAB MRTU Type I, wiring from RH FAB MRTU Type I to pilot DAP, pilot
DAP. Troubleshoot wiring to isolate fault (TM 9127022123).
730 SIGNAL NAME:
ORT SYMBOLOGY BRIGHT ADJ (ACY) CPG SYM BRT ADJ (ACZ)
MEMORY LOCATION: 000433
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor ORT symbol generator display as brightness level is adjusted from minimum
() to maximum (+).
SIGNAL FUNCTION:
Controls optical relay tube (ORT) symbol generator brightness.
REMARKS: From ORT through CPG MRTU Type III to FCC.
PASS:
If condition is met refer to failure symptom index and next failure symptom paragraph.
FAIL: Location of fault: ORT, wiring from ORT to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 9127022123).
731 SIGNAL NAME:
ORT IHADSS CONTRAST ADJ (ACY) CPG CTRS ADJ (ACZ)
MEMORY LOCATION: 000432
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor ORT IHAD display as contrast level is adjusted from minimum () to maximum
(+).
SIGNAL FUNCTION:
Controls IHADSS contrast.
REMARKS: From ORT through CPG MRTU Type III to FCC.
PASS:
If condition is met go to paragraph 732.
FAIL: Location of fault: ORT, wiring from ORT to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 9127022123).
732 SIGNAL NAME:
ORT IHADSS CONTRAST TO TEU (ACY) CPG CTRS ADJ TST (ACZ)
MEMORY LOCATION: 001257
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor ORT IHAD contrast signal level to TEU as level is adjusted from minimum ()
to maximum (+).
SIGNAL FUNCTION:
Provides indication of ORT control outputs to TEU.
REMARKS: From FCC to TEU.
PASS:
If condition is met go to paragraph 733.
FAIL: Location of fault: LH FAB MRTU Type I, wiring from LH FAB MRTU Type I to TEU, TEU.
Troubleshoot wiring to isolate fault (TM 11270476T).