TM 11520238T3
718
Change 4
763 SIGNAL NAME:
PLT VIDEO SEL SW (ACZ)
MEMORY LOCATION: 001120
MEMORY DATA BIT(S):
8
(BINARY)
CONDITION:
If fourth digit on HOD is 2 or 3=CPG
If fourth digit on HOD is 4 or 5=GR SCALE
If fourth digit on HOD is 6 or 7=PILOT
SIGNAL FUNCTION:
Selects grey scale for helmet mounted display (HMD) calibration.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If fourth digit on HOD is 0, 1, 4, 5, 6 or 7, go to Chapter 15, paragraph 1563.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 9127022123).