TM 11520238T3
830
Change 4
890 SIGNAL NAME:
P1M1 MSL SKR INPUT SLAVE (ACY) P1M1 SKR SLV SEL (ACZ)
MEMORY LOCATION: 001274
MEMORY DATA BIT(S):
68
(OCTAL)
CONDITION:
If the fifth digit is 0 or 4 and the fourth digit
is 0 or 2=ZERO EL ZERO AZ
If the fifth digit is 0 or 4 and the fourth digit
is 4 or 6=REMEL REMAZ
If the fifth digit is 1 or 5 and the fourth digit
is 0 or 2=AUTOEL AUTOAZ
If the fifth digit is 1 or 5 and the fourth digit
is 4 or 6=REMEL REMAZ + BIAS/2
If the fifth digit is 2 or 6 and the fourth digit
is 0 or 2=REMEL REMAZ + BIAS
If the fifth digit is 2 or 6 and the fourth digit
is 4 or 6=REMEL REMAZ BIAS/2
If the fifth digit is 3 or 7 and the fourth digit
is 0 or 2=REMEL REMAZ BIAS
If the fifth digit is 3 or 7 and the fourth digit
is 4 or 6=AUTOEL ZERO AZ
SIGNAL FUNCTION:
Selects pitch and yaw slave commands to be applied to missile.
REMARKS: From RHE to ECSP.
PASS:
If CONDITION corresponds to selected seeker input, go to paragraph 891.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
891 SIGNAL NAME:
P1M1 MSL SKR INPUT SLAVE (ACY) P1M1 SKR SLV SEL (ACZ)
MEMORY LOCATION: 001710
MEMORY DATA BIT(S):
68
(OCTAL)
CONDITION:
If the fifth digit is 0 or 4 and the fourth digit
is 0 or 2=ZERO EL ZERO AZ
If the fifth digit is 0 or 4 and the fourth digit
is 4 or 6=REMEL REMAZ
If the fifth digit is 1 or 5 and the fourth digit
is 0 or 2=AUTOEL AUTOAZ
If the fifth digit is 1 or 5 and the fourth digit
is 4 or 6=REMEL REMAZ + BIAS/2
If the fifth digit is 2 or 6 and the fourth digit
is 0 or 2=REMEL REMAZ + BIAS
If the fifth digit is 2 or 6 and the fourth digit
is 4 or 6=REMEL REMAZ BIAS/2
If the fifth digit is 3 or 7 and the fourth digit
is 0 or 2=REMEL REMAZ BIAS
If the fifth digit is 3 or 7 and the fourth digit
is 4 or 6=AUTOEL ZERO AZ
SIGNAL FUNCTION:
Selects pitch and yaw slave commands to be applied to missile.
REMARKS: From launcher through left outboard MRTU Type II to FCC.
PASS:
If CONDITION corresponds to selected seeker input, refer to failure symptom index and next
failure symptom paragraph.
FAIL: Location of fault: left outboard launcher, wiring from left outboard launcher to left outboard
MRTU Type II, left outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).