TM 1–1520–238–T–3Change 48–338–100 SIGNAL NAME:P1M1 MSL SKR POWER CONTROL (ACY) P1M1 SKR PWR OK (ACZ)MEMORY LOCATION: 001274MEMORY DATA BIT(S):13(BINARY)CONDITION:(None)SIGNAL FUNCTION:Controls application of seeker power.REMARKS: From RHE to ECSP.PASS:If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8–101.FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).8–101 SIGNAL NAME:P1M1 MSL SKR POWER CONTROL (ACY) P1M1 SKR PWR OK (ACZ)MEMORY LOCATION: 001710MEMORY DATA BIT(S):13(BINARY)CONDITION:(None)SIGNAL FUNCTION:Controls application of seeker power.REMARKS: From launcher through left outboard MRTU Type II to FCC.PASS:If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8–102.FAIL: Location of fault: left outboard launcher, wiring from left outboard launcher to left outboardMRTU Type II, left outboard MRTU Type II. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).8–102 SIGNAL NAME:P1M1 MSL SKR POWERMEMORY LOCATION: 001413MEMORY DATA BIT(S):12(BINARY)CONDITION:(None)SIGNAL FUNCTION:Indicates status of seeker power (+28 VDC).REMARKS: From ECSP to RHE.PASS:If third digit on HOD is 2, 3, 6, or 7, go to paragraph 8–103.FAIL: Location of fault: RHE, wiring from RHE to left outboard launcher, left outboard launcher.Troubleshoot wiring to isolate fault (TM 9–1427–475–20).8–103 SIGNAL NAME:P1M1 MSL SEEKER POWER (ACY) P1M1 SKR PWR OK (ACZ)MEMORY LOCATION: 001671MEMORY DATA BIT(S):12(BINARY)CONDITION:(None)SIGNAL FUNCTION:Indicates status of seeker power (+28 VDC).REMARKS: From launcher through left outboard MRTU Type II to FCC.PASS:If third digit on HOD is 2, 3, 6, or 7, go to paragraph 8–106.FAIL: Location of fault: left outboard launcher, wiring from left outboard launcher to left outboardMRTU Type II, left outboard MRTU Type II. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).8–104 SIGNAL NAME:P1M1 CCM ACTIVATE CMDMEMORY LOCATION: 001274MEMORY DATA BIT(S):14(BINARY)CONDITION:(None)SIGNAL FUNCTION:Commands missile seeker to enter counter countermeasure (CCM) mode.REMARKS: From RHE to ECSP.PASS:If second digit on HOD is 4, 5, 6, or 7, go to paragraph 8–107.FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business