TM 11520238T3
Change 4
8109
8398 SIGNAL NAME:
P2M2 UNLATCH INDICATE
MEMORY LOCATION: 001737
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates to operator when a missile is unlatched.
REMARKS: From launcher through left inboard MRTU Type II to FCC for display.
PASS:
If first digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 8399.
FAIL: Location of fault: left inboard launcher, wiring from left inboard launcher to left inboard MRTU
Type II, left inboard MRTU Type II. Troubleshoot wiring to isolate fault (TM 9142747520).
8399 SIGNAL NAME:
P2M2 UNLATCH INDICATE
MEMORY LOCATION: 001762
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates to operator when a missile is unlatched.
REMARKS: From FCC through left inboard MRTU Type II to launcher.
PASS:
If first digit displayed on HOD is 0, 1, 2, or 3, refer to failure symptom index and next failure
symptom paragraph.
FAIL: Location of fault: left inboard MRTU Type II, wiring from left inboard MRTU Type II to FCC,
FCC. Troubleshoot wiring to isolate fault (TM 91230476202).
8400 SIGNAL NAME:
P2M2 UPPER LOWER DISPLAY STATUS (ACY) P2M2 PRIORITY IND (ACZ)
MEMORY LOCATION: 001353
MEMORY DATA BIT(S):
8
(BINARY)
CONDITION:
If the second digit displayed on HOD is 0, 2, 4, or 6=UPPER
If the second digit displayed on HOD is 1, 3, 5, or 7=LOWER
SIGNAL FUNCTION:
Indicates to operator when a selected missile has been assigned to upper or
lower channel.
REMARKS: From RHE to FCC for display.
PASS:
If CONDITION corresponds to selected channel, go to paragraph 8401.
FAIL: Location of fault: replace RHE (TM 9142747520).
8401 SIGNAL NAME:
P2M2 TYPE STATUS DISPLAY (ACY) P2M2 TYPE (ACZ)
MEMORY LOCATION: 001353
MEMORY DATA BIT(S):
1719
(OCTAL)
CONDITION:
If the first digit displayed on HOD is 0=NONE
If the first digit displayed on HOD is 1=TACTICAL LASER
If the first digit displayed on HOD is 4=UNIDENTIFIED
If the first digit displayed on HOD is 5=TRAINING LASER
SIGNAL FUNCTION:
Provides type of missile data for display to operator.
REMARKS: From RHE to FCC for display.
PASS:
If CONDITION on HOD corresponds to installed type of missiles, go to paragraph 8402.
FAIL: Location of fault: replace: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate
fault (TM 9142747520).
