TM 11520238T3
8114
Change 4
8416 SIGNAL NAME:
P2M2 MSL SKR POWER CONTROL (ACY) P2M2 SKR PWR OK (ACZ)
MEMORY LOCATION: 001317
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Controls application of seeker power.
REMARKS: From RHE to ECSP.
PASS:
If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8417.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8417 SIGNAL NAME:
P2M2 MSL SKR POWER CONTROL (ACY) P2M2 SKR PWR OK (ACZ)
MEMORY LOCATION: 001754
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Controls application of seeker power.
REMARKS: From launcher through left inboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8418.
FAIL: Location of fault: left inboard launcher, wiring from left inboard launcher to left inboard MRTU
Type II, left inboard MRTU Type II. Troubleshoot wiring to isolate fault (TM 9142747520).
8418 SIGNAL NAME:
P2M2 MSL SKR POWER
MEMORY LOCATION: 001417
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of seeker power (+28 VDC).
REMARKS: From ECSP to RHE.
PASS:
If third digit on HOD is 2, 3, 6, or 7, go to paragraph 8419.
FAIL: Location of fault: replace left inboard launcher (TM 91425475302).
8419 SIGNAL NAME:
P2M2 MSL SEEKER POWER (ACY) P2M2 SKR PWR OK (ACZ)
MEMORY LOCATION: 001735
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of seeker power (+28 VDC).
REMARKS: From launcher through left inboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 2, 3, 6, or 7, go to paragraph 8422.
FAIL: Location of fault: left inboard launcher, wiring from left inboard launcher to left inboard MRTU
Type II, left inboard MRTU Type II. Troubleshoot wiring to isolate fault (TM 9142747520).
8420 SIGNAL NAME:
P2M2 CCM ACTIVATE CMD
MEMORY LOCATION: 001317
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands missile seeker to enter CCM mode.
REMARKS: From RHE to ECSP.
PASS:
If second digit on HOD is 4, 5, 6, or 7, go to paragraph 8421.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
