TM 11520238T3
Change 4
8195
8732 SIGNAL NAME:
P3M3 MSL SKR POWER CONTROL (ACY) P3M3 SKR PWR OK (ACZ)
MEMORY LOCATION: 001327
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Controls application of seeker power.
REMARKS: From RHE to ECSP.
PASS:
If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8733.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8733 SIGNAL NAME:
P3M3 MSL SKR POWER CONTROL (ACY) P3M3 SKR PWR OK (ACZ)
MEMORY LOCATION: 002020
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Controls application of seeker power.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8734.
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboard
MRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8734 SIGNAL NAME:
P3M3 MSL SKR POWER
MEMORY LOCATION: 001423
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of seeker power (+28 VDC).
REMARKS: From ECSP to RHE.
PASS:
If third digit on HOD is 2, 3, 6, or 7, go to paragraph 8735.
FAIL: Location of fault: replace launcher (TM 91425475302).
8735 SIGNAL NAME:
P3M3 MSL SEEKER POWER (ACY) P3M3 SKR PWR OK (ACZ)
MEMORY LOCATION: 002001
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of seeker power (+28 VDC).
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 2, 3, 6, or 7, go to paragraph 8738.
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboard
MRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8736 SIGNAL NAME:
P3M3 CCM ACTIVATE CMD
MEMORY LOCATION: 001327
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands missile seeker to enter CCM mode.
REMARKS: From RHE to ECSP.
PASS:
If second digit on HOD is 4, 5, 6, or 7, go to paragraph 8737.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).