TM 11520238T3
8200
8753 SIGNAL NAME:
P3M3 MSL DEICE #2 CMD
MEMORY LOCATION: 002024
MEMORY DATA BIT(S):
4
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Issues deicing squib fire command to selected missile.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If sixth digit on HOD is 1, go to paragraph 81118.
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboard
MRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8754 SIGNAL NAME:
P3M3 MSL BIT CONTROL
MEMORY LOCATION: 001333
MEMORY DATA BIT(S):
69
(HEX)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands BIT on autopilot.
REMARKS: From RHE to ECSP.
PASS:
If fifth digit displayed on HOD is 0, 1, or 2, and the fourth digit displayed on HOD is 2, 3, 4, 5,
6, or 7 go to paragraph 8755.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8755 SIGNAL NAME:
P3M3 MSL BIT CONTROL
MEMORY LOCATION: 002024
MEMORY DATA BIT(S):
69
(HEX)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands BIT on autopilot.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
Location of fault if fifth digit displayed on HOD is 0, 1, or 2, and the fourth digit displayed on
HOD is 2, 3, 4, 5, 6, or 7: Replace right inboard launcher missile 3 (TM 9142747520).
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboard
MRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8756 SIGNAL NAME:
P3M3 MSL INDIRECT FIRE LO
MEMORY LOCATION: 001333
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands low flight profile for LOAL operation.
REMARKS: From RHE to ECSP.
PASS:
If fourth digit on HOD is 1, 3, 5, or 7, go to paragraph 8757.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).