TM 1–1520–238–T–38–3028–1150 SIGNAL NAME:MSL LOWER CHANNEL CODE COMMANDMEMORY LOCATION: 001441MEMORY DATA BIT(S):17–19(OCTAL)CONDITION:If the first digit displayed on HOD is 0=HIf the first digit displayed on HOD is 1=GIf the first digit displayed on HOD is 2=FIf the first digit displayed on HOD is 3=EIf the first digit displayed on HOD is 4=DIf the first digit displayed on HOD is 5=CIf the first digit displayed on HOD is 6=BIf the first digit displayed on HOD is 7=ASIGNAL FUNCTION:Indicates which of eight laser codes of the day is selected in the lowerpushbutton index select switch.REMARKS: From CPG FCP to RHE.PASS:If first digit on HOD corresponds to selected code, go to paragraph 8–1151.FAIL: Location of fault: CPG FCP, wiring from CPG FCP to RHE, RHE. Troubleshoot wiring to isolatefault (TM 9–1427–475–20).8–1151 SIGNAL NAME:MSL LOWER CHANNEL CODE SWMEMORY LOCATION: 000437MEMORY DATA BIT(S):4–6(OCTAL)CONDITION:If the sixth digit displayed on HOD is 0 and the fifth digit is 0 or1=HIf the sixth digit displayed on HOD is 0 and the fifth digit is 2 or 3=GIf the sixth digit displayed on HOD is 0 and the fifth digit is 4 or 5=FIf the sixth digit displayed on HOD is 0 and the fifth digit is 6 or 7=EIf the sixth digit displayed on HOD is 1 and the fifth digit is 0 or 1=DIf the sixth digit displayed on HOD is 1 and the fifth digit is 2 or 3=CIf the sixth digit displayed on HOD is 1 and the fifth digit is 4 or 5=BIf the sixth digit displayed on HOD is 1 and the fifth digit is 6 or 7=ASIGNAL FUNCTION:Indicates CPG has selected lower laser coding.REMARKS: From CPG FCP through CPG MRTU Type III to RHE.PASS:If CONDITION corresponds to selected code, go to paragraph 8–1152.FAIL: Location of fault: CPG FCP, wiring from CPG FCP to CPG MRTU Type III, CPG MRTU Type III.Troubleshoot wiring to isolate fault (TM 9–1427–475–20).8–1152 SIGNAL NAME:MSL LOWER CHANNEL CODEMEMORY LOCATION: 001343MEMORY DATA BIT(S):17–19(OCTAL)CONDITION:If the first digit displayed on HOD is 0=HIf the first digit displayed on HOD is 1=GIf the first digit displayed on HOD is 2=FIf the first digit displayed on HOD is 3=EIf the first digit displayed on HOD is 4=DIf the first digit displayed on HOD is 5=CIf the first digit displayed on HOD is 6=BIf the first digit displayed on HOD is 7=ASIGNAL FUNCTION:Indicates lower laser code being used by RHE.REMARKS: From RHE to FCC.PASS:If first digit on HOD corresponds to selected code, go to paragraph 8–1155.FAIL: Location of fault: replace RHE (TM 9–1427–475–20).
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business