TM 11520238T3
106
Change 4
1017 SIGNAL NAME:
ORT PNVS VIDEO SELECT (ACY) PNVS VIDEO SW TST (ACZ)
MEMORY LOCATION: 001252
MEMORY DATA BIT(S):
4
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates CPG has selected PNVS video.
REMARKS: From FCC through LH FAB MRTU Type I to TEU.
PASS:
If sixth digit on HOD is 1, go to paragraph 1018.
FAIL: Location of fault: ORT, wiring from ORT to FCC, LH FAB MRTU Type I,wiring from LH FAB
MRTU Type I to TEU, TEU. Troubleshoot wiring to isolate fault (TM 11270476T).
1018 SIGNAL NAME:
PLT FCP LEVEL ADJ
MEMORY LOCATION: 001077
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
Monitor HOD while increasing level; memory location response should increase when
level is increased and decrease when level is decreased.
SIGNAL FUNCTION:
Adjusts forward looking infrared radar (FLIR) video.
REMARKS: From pilot fire control panel (FCP) through LH FAB MRTU Type I to FCC.
PASS:
If CONDITION has been met, go to paragraph 1019.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).
1019 SIGNAL NAME:
PLT FCP GAIN ADJ
MEMORY LOCATION: 001100
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
Monitor HOD while increasing gain; memory location response should increase when
gain is increased and decrease when gain is decreased.
SIGNAL FUNCTION:
Adjusts FLIR gain.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If CONDITION has been met, go to paragraph 1020.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).
1020 SIGNAL NAME:
PLT FCP BRIGHT ADJ
MEMORY LOCATION: 001103
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
Monitor HOD while increasing brightness; memory location response should increase
when brightness is increased and decrease when when brightness is decreased.
SIGNAL FUNCTION:
Adjusts video.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If CONDITION has been met, go to paragraph 1021.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).