TM 11520238T3
Change 4
107
1021 SIGNAL NAME:
PLT FCP CONTRAST ADJ
MEMORY LOCATION: 001104
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
Monitor HOD while increasing contrast; memory location response should increase
when contrast is increased and decrease when when contrast is decreased.
SIGNAL FUNCTION:
Adjusts contrast.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If CONDITION has been met, go to paragraph 1022.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).
1022 SIGNAL NAME:
GAIN TO PNVS (AAD) PNVS GAIN CMD (ACZ)
MEMORY LOCATION: 001624
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
Monitor HOD while increasing gain; memory location response should increase when
gain is increased and decrease when when gain is decreased.
SIGNAL FUNCTION:
Controls gain of FLIR.
REMARKS: From FCC through RH FAB MRTU Type I to TADS/PNVS turret assembly.
PASS:
If CONDITION has been met, go to paragraph 1023.
FAIL: Location of fault: RH FAB MRTU Type I, wiring from RH FAB MRTU Type I through RH FAB
crossover to TADS/PNVS turret assembly. Troubleshoot wiring to isolate fault
(TM 15855265T).
1023 SIGNAL NAME:
LEVEL TO PNVS (AAD) PNVS LEVEL CMD (ACZ)
MEMORY LOCATION: 001625
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
Monitor HOD while increasing level; memory location response should increase when
level is increased and decrease when level is decreased.
SIGNAL FUNCTION:
Controls brightness of FLIR.
REMARKS: From FCC through RH FAB MRTU Type I to TADS/PNVS turret assembly.
PASS:
If CONDITION has been met , replace PEU (TM 115855265201).
FAIL: Location of fault: RH FAB MRTU Type I, wiring from RH FAB MRTU Type I through RH FAB
crossover to TADS/PNVS turret assembly. Troubleshoot wiring to isolate fault
(TM 15855265T).
1024 SIGNAL NAME:
PLT FCP ACM SW
MEMORY LOCATION: 001117
MEMORY DATA BIT(S):
9
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Selects optimum gain of night vision sensor.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If fourth digit on HOD is 0, 1, 4, or 5, go to paragraph 1025.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).