TM 11520238T3
1436
14157 SIGNAL NAME:
CPG CHAR 11, 12
MEMORY LOCATION: 000741
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays CPG characteristics 11 and 12.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14158.
FAIL: Location of fault: replace FCC (TM 91230476201).
14158 SIGNAL NAME:
CPG CHAR 13, 14
MEMORY LOCATION: 000742
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays CPG characters 13 and 14.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14159.
FAIL: Location of fault: replace FCC (TM 91230476201).
14159 SIGNAL NAME:
CPG CHAR 15, 16
MEMORY LOCATION: 000743
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays CPG characters 15 and 16.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14160.
FAIL: Location of fault: replace FCC (TM 91230476201).
14160 SIGNAL NAME:
CPG CHAR 17, 18
MEMORY LOCATION: 000744
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays CPG characters 17 and 18.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14161.
FAIL: Location of fault: replace FCC (TM 91230476201).
14161 SIGNAL NAME:
CPG CHAR 19, 20
MEMORY LOCATION: 000745
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays CPG characters 19 and 20.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14162.
FAIL: Location of fault: replace FCC (TM 91230476201).