TM 11520238T3
1441
14182 SIGNAL NAME:
PLT CHAR 29, 30
MEMORY LOCATION: 000772
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays pilot characters 29 and 30.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14183.
FAIL: Location of fault: replace FCC (TM 91230476201).
14183 SIGNAL NAME:
STATUS DISPLAY MSG CONT
MEMORY LOCATION: 000776
MEMORY DATA BIT(S):
11
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Enables status lines and characters.
REMARKS: From FCC to symbol generator.
PASS:
If the third digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 14184.
FAIL: Location of fault: replace FCC (TM 91230476201).
14184 SIGNAL NAME:
STATUS L1 CHAR 1, 2
MEMORY LOCATION: 000776
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 1 characters 1 and 2.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14185.
FAIL: Location of fault: replace FCC (TM 91230476201).
14185 SIGNAL NAME:
STATUS L1 CHAR 3, 4
MEMORY LOCATION: 000777
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 1 characters 3 and 4.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14186.
FAIL: Location of fault: replace FCC (TM 91230476201).
14186 SIGNAL NAME:
STATUS L1 CHAR 5, 6
MEMORY LOCATION: 001000
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 1 characters 5 and 6.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14187.
FAIL: Location of fault: replace FCC (TM 91230476201).