TM 11520238T3
1447
14212 SIGNAL NAME:
STATUS L3 CHAR 9, 10
MEMORY LOCATION: 001034
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 3 characters 9 and 10.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14213.
FAIL: Location of fault: replace FCC (TM 91230476201).
14213 SIGNAL NAME:
STATUS L3 CHAR 11, 12
MEMORY LOCATION: 001035
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 3 characters 11 and 12.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14214.
FAIL: Location of fault: replace FCC (TM 91230476201).
14214 SIGNAL NAME:
STATUS L3 CHAR 13, 14
MEMORY LOCATION: 001036
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 3 characters 13 and 14.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14215.
FAIL: Location of fault: replace FCC (TM 91230476201).
14215 SIGNAL NAME:
STATUS L3 CHAR 15, 16
MEMORY LOCATION: 001037
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 3 characters 15 and 16.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14216.
FAIL: Location of fault: replace FCC (TM 91230476201).
14216 SIGNAL NAME:
STATUS L3 CHAR 17, 18
MEMORY LOCATION: 001040
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 3 characters 17 and 18.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14217.
FAIL: Location of fault: replace FCC (TM 91230476201).