TM 11520238T3
1445
14202 SIGNAL NAME:
STATUS L2 CHAR 13, 14
MEMORY LOCATION: 001020
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 2 characters 13 and 14.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14203.
FAIL: Location of fault: replace FCC (TM 91230476201).
14203 SIGNAL NAME:
STATUS L2 CHAR 15, 16
MEMORY LOCATION: 001021
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 2 characters 15 and 16.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14204.
FAIL: Location of fault: replace FCC (TM 91230476201).
14204 SIGNAL NAME:
STATUS L2 CHAR 17, 18
MEMORY LOCATION: 001022
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 2 characters 17 and 18.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14205.
FAIL: Location of fault: replace FCC (TM 91230476201).
14205 SIGNAL NAME:
STATUS L2 CHAR 19, 20
MEMORY LOCATION: 001023
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 2 characters 19 and 20.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14206.
FAIL: Location of fault: replace FCC (TM 91230476201).
14206 SIGNAL NAME:
STATUS L2 CHAR 21, 22
MEMORY LOCATION: 001024
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 141 for ASCII code conversions.
SIGNAL FUNCTION:
Displays status line 2 characters 21 and 22.
REMARKS: From FCC to symbol generator.
PASS:
If ASCII code conversions correspond to selected character, go to paragraph 14207.
FAIL: Location of fault: replace FCC (TM 91230476201).