1510
1529 SIGNAL NAME:
STATUS WORD
MEMORY LOCATION: 001157
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors TADS.
REMARKS: From TADS to LH FAB MRTU Type I.
PASS:
If fourth digit on HOD is 0, 2, 4, or 6, go to paragraph 1530.
FAIL: Location of fault: go to paragraph 1532.
1530 SIGNAL NAME:
STATUS WORD
MEMORY LOCATION: 000620
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors lines 1 and 2 of alphanumeric display (AND).
REMARKS: From AND to CPG MRTU Type III.
PASS:
If fourth digit on HOD is 0, 2, 4, or 6, go to paragraph 1564.
FAIL: Location of fault: replace AND (TM 1127047620).
1531 SIGNAL NAME:
STATUS WORD
MEMORY LOCATION: 000652
MEMORY DATA BIT(S):
10
(BINARY)
SIGNAL FUNCTION:
Monitors lines 3 and 4 of AND.
REMARKS: From AND to CPG MRTU Type III.
PASS:
If fourth digit on HOD is 0, 2, 4, or 6, go to paragraph 1588.
FAIL: Location of fault: replace AND (TM 1127047620).
1532 SIGNAL NAME:
ECS SYSTEM STATUS
MEMORY LOCATION: 001136
MEMORY DATA BIT(S):
5
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors TADS environmental control system (ECS) assembly.
REMARKS: From TEU through LH FAB MRTU Type I to FCC.
PASS:
If fifth digit on HOD is 4, 5, 6, or 7, go to paragraph 1533.
FAIL: Location of fault: TADS ECS, ECS, ECS assembly vacuum hose, wiring from ECS to aircraft
interface adapter (AIA) interface. Troubleshoot wiring to isolate fault (TM 11270476T).
1533 SIGNAL NAME:
TEU HANDSHAKE
MEMORY LOCATION: 001141
MEMORY DATA BIT(S):
4
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors serial input line.
REMARKS: From TEU through LH FAB MRTU Type I to FCC.
PASS:
If sixth digit on HOD is 0, go to paragraph 1534.
FAIL: Location of fault: replace TEU (TM 1127047620).