TM 11520238T3
2014
2032 SIGNAL NAME:
DOP TRACK ANGLE ERROR
MEMORY LOCATION: 000467
MEMORY DATA BIT(S):
74
(HEX)
CONDITION:
If first digit displayed on HOD is 0, and second digit is 0, 2, 4, or 6=0
If first digit displayed on HOD is 1, and second digit is 0, 2, 4, or 6=1
If first digit displayed on HOD is 2, and second digit is 0, 2, 4, or 6=2
If first digit displayed on HOD is 3, and second digit is 0. 2. 4, or 6=3
If first digit displayed on HOD is 4, and second digit is 0, 2, 4, or 6=4
If first digit displayed on HOD is 5, and second digit is 0, 2, 4, or 6=5
If first digit displayed on HOD is 6, and second digit is 0, 2, 4, or 6=6
If first digit displayed on HOD is 7, and second digit is 0, 2, 4, or 6=7
If first digit displayed on HOD is 0, and second digit is 4, 5, 6, or 7=8
If first digit displayed on HOD is 1, and second digit is 1, 3, 5, or 7=9
SIGNAL FUNCTION:
Indicates tenths field.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with track angle, go to paragraph 2047.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).
2033 SIGNAL NAME:
DOP COSINE ROLL
MEMORY LOCATION: 000471
MEMORY DATA BIT(S):
1817
(BINARY)
CONDITION:
If fifth digit displayed on HOD is 0 or 1=plus, north, west, up, to
If fifth digit displayed on HOD is 2 or 3=failure warning
If fifth digit displayed on HOD is 4 or 5=no computed data and no failure detected
If fifth digit displayed is 6 or 7=minus, south, east , down, from
SIGNAL FUNCTION:
Indicates sine/status of Doppler.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with attitude, go to paragraph 2034.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault. (TM 111520238232).
2034 SIGNAL NAME:
DOP COSINE ROLL
MEMORY LOCATION: 000471 AND 000472
MEMORY DATA BIT(S):
164 AND 1918
(SCALAR)
CONDITION:
Monitor HOD; memory location response should indicate a positive if aircraft is in right
roll or negative if aircraft is in left roll.
SIGNAL FUNCTION:
Indicates Doppler cosine roll.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with attitude, go to paragraph 2035.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).