TM 11520238T3
209
2018 SIGNAL NAME:
DOP NORTHING
MEMORY LOCATION: 000457
MEMORY DATA BIT(S):
74
(HEX)
CONDITION:
If first digit displayed on HOD is 0, and second digit is 0, 2, 4, or 6=0
If first digit displayed on HOD is 1, and second digit is 0, 2, 4, or 6=1
If first digit displayed on HOD is 2, and second digit is 0, 2, 4, or 6=2
If first digit displayed on HOD is 3, and second digit is 0. 2. 4, or 6=3
If first digit displayed on HOD is 4, and second digit is 0, 2, 4, or 6=4
If first digit displayed on HOD is 5, and second digit is 0, 2, 4, or 6=5
If first digit displayed on HOD is 6, and second digit is 0, 2, 4, or 6=6
If first digit displayed on HOD is 7, and second digit is 0, 2, 4, or 6=7
If first digit displayed on HOD is 0, and second digit is 1, 3, 5, or 7=8
If first digit displayed on HOD is 1, and second digit is 1, 3, 5, or 7=9
SIGNAL FUNCTION:
Indicates tenths field.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with heading, go to paragraph 2019.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).
2019 SIGNAL NAME:
DOP NORTHING
MEMORY LOCATION: 000460
MEMORY DATA BIT(S):
1916
(HEX)
CONDITION:
If fifth digit displayed on HOD is 0, and sixth digit is 0=0
If fifth digit displayed on HOD is 1, and sixth digit is 0=1
If fifth digit displayed on HOD is 2, and sixth digit is 0=2
If fifth digit displayed on HOD is 3, and sixth digit is 0=3
If fifth digit displayed on HOD is 4, and sixth digit is 0=4
If fifth digit displayed on HOD is 5, and sixth digit is 0=5
If fifth digit displayed on HOD is 6, and sixth digit is 0=6
If fifth digit displayed on HOD is 7, and sixth digit is 0=7
If fifth digit displayed on HOD is 0, and sixth digit is 1=8
If fifth digit displayed on HOD is 1, and sixth digit is 1=9
SIGNAL FUNCTION:
Indicates hundredths field.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with heading, go to paragraph 2020.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).
2020 SIGNAL NAME:
DOP COS PITCH
MEMORY LOCATION: 000461
MEMORY DATA BIT(S):
1817
(BINARY)
CONDITION:
If fifth digit displayed on HOD is 0 or 1=plus, north, west, up, to
If fifth digit displayed on HOD is 2 or 3=failure warning
If fifth digit displayed on HOD is 4 or 5=no computed data and no failure detected
If fifth digit displayed on HOD is 6 or 7=minus, south, east, down, from
SIGNAL FUNCTION:
Indicates sign/status of Doppler.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with heading, go to paragraph 2021.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).
