TM 11520238T3
Change 5
231
CHAPTER 23
RADAR ALTIMETER (RADALT) MULTIPLEX READ CODES
FAILURE SYMPTOM INDEX
Symptom
Refer to paragraph
OFF FLAG IS VISIBLE AND RHI DOES NOT INDICATE 0 (5/ +5) FEET . . .
231
VDU DISPLAY ALTITUDE LO WARNING IS NOT DISPLAYED . . . . . . . . . . . . .
233
VDU DOES NOT DISPLAY 1000 (100/ +100) FEET . . . . . . . . . . . . . . . . . . . . .
235
VDU DISPLAY ALTITUDE HI WARNING IS NOT DISPLAYED . . . . . . . . . . . . .
237
Personnel Required:
(2)
References:
TM 91230476201
TM 111520238232
TM 111520238231
Equipment Conditions:
Ref
Condition
TM 111520238232
RADAR ALTIMETER
MAINTENANCE
OPERATIONAL CHECK in
progress
NOTE
All multiplex read code responses are read from right to
left.
Multiplex read codes must be used in conjunction with
applicable Maintenance Operational Check (MOC) in
progress.
Multiplex read codes are observed on the HOD (ADC) or
CDU (ADD).
MULTIPLEX READ CODE INTERPRETATIONS
231 SIGNAL NAME:
PILOT RADALT CONT
MEMORY LOCATION: 000677
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors radar altimeter (RADALT) ON/OFF status.
REMARKS: From FCC to receivertransmitter.
PASS:
If first digit displayed on the HOD is 0, 2, 4, or 6, go to paragraph 232.
FAIL: Location of fault: remote height indicator (RHI), wiring from remote height indicator to
receivertransmitter, receivertransmitter. Troubleshoot wiring to isolate fault
(TM 111520238232).