TM 11520238T3
242
Change 4
242 SIGNAL NAME:
CPG MISSILE INDICATOR (ACY) CPG MSL LIGHT (ACZ)
MEMORY LOCATION: 000565
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors missile system.
REMARKS: From FCC through CPG MRTU Type III to CPG caution/warning panel.
PASS:
If second digit displayed on HOD is 1, 3, 5, or 7, go to Chapter 8, paragraph 81.
FAIL: Location of fault: CPG MRTU Type III, wiring from CPG MRTU Type III to CPG caution/warning
panel, CPG caution/warning panel. Troubleshoot wiring to isolate fault (TM 11520238T6).
243 SIGNAL NAME:
CPG TADS INDICATOR (ACY) CPG TADS LIGHT (ACZ)
MEMORY LOCATION: 000565
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors TADS system.
REMARKS: From FCC through CPG MRTU Type III to CPG caution/warning panel.
PASS:
If first digit displayed on HOD is 4, 5, 6, or 7, go to Chapter 15, paragraph 1526.
FAIL: Location of fault: CPG MRTU Type III, wiring from CPG MRTU Type III to CPG caution/warning
panel, CPG caution/warning panel. Troubleshoot wiring to isolate fault (TM 11520238T6).
244 SIGNAL NAME:
CPG GUN INDICATOR (ACY) CPG GUN LIGHT (ACZ)
MEMORY LOCATION: 000565
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors gun system.
REMARKS: From FCC through CPG MRTU Type III to CPG caution/warning panel.
PASS:
If first digit displayed on HOD is 2, 3, 6, or 7, go to Chapter 5, paragraph 53.
FAIL: Location of fault: CPG MRTU Type III, wiring from CPG MRTU Type III to CPG caution/warning
panel, CPG caution/warning panel. Troubleshoot wiring to isolate fault (TM 11520238T6).
245 SIGNAL NAME:
CPG ROCKET INDICATOR (ACY) CPG RKT LIGHT (ACZ)
MEMORY LOCATION: 000565
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors rocket system.
REMARKS: From FCC through CPG MRTU Type III to CPG caution/warning panel.
PASS:
If first digit displayed on HOD is 1, 3, 5, or 7, go to Chapter 12, paragraph 126.
FAIL: Location of fault: CPG MRTU Type III, wiring from CPG MRTU Type III to CPG caution/warning
panel, CPG caution/warning panel. Troubleshoot wiring to isolate fault (TM 11520238T6).