TM 11520238T3
Change 5
283
287 SIGNAL NAME:
ZEROIZE IN PROGRESS
MEMORY LOCATION: 002523
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
ZEROIZE selected on CDU.
SIGNAL FUNCTION:
Indicates zeroing of DTC in progress.
REMARKS: From DTU to FCC.
PASS:
If the second digit on the CDU is 1, go to paragraph 288.
FAIL: Location of fault: CDU, wiring from CDU to zeroize relay, zeroize relay, wiring from zeroize relay
to DTR, DTR. Troubleshoot wiring to isolate fault (TM 111520238232).
288 SIGNAL NAME:
ZEROIZE SUCCESFUL
MEMORY LOCATION: 002523
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
ZEROIZE selected on CDU.
SIGNAL FUNCTION:
Indicates DTC is zeroized.
REMARKS: From DTU to FCC.
PASS:
If the second digit on the CDU is 2, replace DTC (TM 111520238231).
FAIL: Location of fault: Replace DTR (TM 111520238231).
289 SIGNAL NAME:
TERMINAL FLAG
MEMORY LOCATION: 002525
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates terminal fault.
REMARKS: From DTU to FCC.
PASS:
If first digit on CDU is 4 or 0, go to paragraph 2810.
FAIL: Location of fault: From DTU circuit breaker to DTR. Troubleshoot wiring to isolate fault
(TM 111520238232).
2810 SIGNAL NAME:
MESSAGE ERROR
MEMORY LOCATION: 002525
MEMORY DATA BIT(S):
9
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicate a message error.
REMARKS: From DTU to FCC.
PASS:
If fourth digit on CDU is 0, go to paragraph 2812.
FAIL: Location of fault: Replace DTR (TM 111520238231).
2811 SIGNAL NAME:
SUBSYSTEM FLAG
MEMORY LOCATION: 002525
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates DTC battery low.
REMARKS: From DTU to FCC.
PASS:
If first digit on CDU is 0, go to paragraph 2814.
FAIL: Location of fault: Replace DTC (TM 111520238231).