TM 11520238T3
Change 5
291
CHAPTER 29
COMPUTER DISPLAY UNIT (CDU) (ADD)
MULTIPLEX READ CODES
FAILURE SYMPTOM INDEX
Symptom
Refer to paragraph
CDU NOGO MESSAGE DISPLAYED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
Personnel Required:
(2)
References:
TM 91230476202
TM 111520238231
TM 111520238232
Equipment Conditions:
Ref
Condition
TM 111520238232
Doppler (ADD)
MAINTENANCE
OPERATIONAL CHECK in
progress
TM 91230476202
MULTIPLEX SUBSYSTEM
POWER UP completed
NOTE
All multiplex read code responses are read from right to
left.
Multiplex read codes must be used in conjunction with
applicable Maintenance Operational Check (MOC) in
progress.
MULTIPLEX READ CODE INTERPRETATIONS
291 SIGNAL NAME:
MESSAGE ERROR
MEMORY LOCATION: 002254
MEMORY DATA BIT(S):
9
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates message error.
REMARKS: From CDU to FCC.
PASS:
If fourth digit displayed on CDU is 0, 1, 4, or 5, go to paragraph 292.
FAIL: Location of fault: replace CDU (TM 111520238231).
292 SIGNAL NAME:
RESERVED
MEMORY LOCATION: 002254
MEMORY DATA BIT(S):
12-14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates serial digital error.
REMARKS: From CDU to FCC.
PASS:
If second and third digits displayed on CDU are 0, go to paragraph 293.
FAIL: Location of fault: replace CDU (TM 111520238231).