Personnel Required:
(2)
References:
TM 111520238231
TM 111520238232
Equipment Conditions:
Ref
Condition
TM 111520238232
Doppler (ADD)
MAINTENANCE
OPERATIONAL CHECK in
progress
TM 91230476202
MULTIPLEX SUBSYSTEM
POWER UP completed
NOTE
All multiplex read code responses are read from right to
left.
Multiplex read codes must be used in conjunction with
applicable Maintenance Operational Check (MOC) in
progress.
MULTIPLEX READ CODE INTERPRETATIONS
301 SIGNAL NAME:
MESSAGE ERROR
MEMORY LOCATION: 003005
MEMORY DATA BIT(S):
9
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates message error.
REMARKS: From SDCC to FCC.
PASS:
If fourth digit displayed on CDU is 0, go to paragraph 302.
FAIL: Location of fault: input correct datum (TM 1152023810). If fault remains, replace FCC
(TM 91230476202).
302 SIGNAL NAME:
SUBSYSTEM FLAG
MEMORY LOCATION: 003005
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates subsystem fault.
REMARKS: From SDCC to FCC.
PASS:
If first digit displayed on CDU is 0 or 1, go to paragraph 303.
FAIL: Location of fault: replace SDCC (TM 111520238231).
303 SIGNAL NAME:
TERMINAL FLAG
MEMORY LOCATION: 003005
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates terminal fault.
REMARKS: From SDCC to FCC.
PASS:
If first digit displayed on CDU is 0, go to paragraph 304.
FAIL: Location of fault: replace SDCC (TM 111520238231).