TM 1-1520-238-T-4
451
412.
POWER PLANTS MAINTENANCE OPERATIONAL CHECK (ENGINE 1) (cont)
412
Task
Result
b. On CPG power quadrant (fig. 427), check
that edgelight panel is lighted.
If CPG power quadrant edgelight panel does not
light, refer to paragraph 462.
M58-061
BAT OVRD
PWR
EDGE-LIGHT
PANEL
ENGINE NO 1
PWR LEVER
ENGINE NO 2
PWR LEVER
Figure 427.
CPG Power Quadrant
c. On pilot power quadrant (fig. 426), set
PWR NO 1 lever to LOCKOUT.
NOTE
Fuel boost pump does not operate through pilot FUEL panel BOOST
switch unless CROSSFEED switch is set to AFT TK.
d. On pilot FUEL panel (fig. 428), set
CROSSFEED switch to AFT TK, ENG 1
FUEL switch to ON, and BOOST switch to
ON.
M58-062
CROSSFEED
SWITCH
BOOST
SWITCH
ENG 2 SWITCH
ENG 1 SWITCH
Figure 428.
Pilot FUEL Panel