TM 1-1520-238-T-4
682.8
Change 5
618.1. HOD NGB 2 READING DISPLAYS 50 LB OIL PRESSURE
618.1
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
TM 55-1500-323-24
TM 9-1230-476-20-2
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R200 access panel and
RN6, R60 fairings open.
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Inspect splice SP1 on red wire from NGB 2 oil
pressure transducer (MT12).
Does open exist?
YES
Repair splice
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Go to step 2.
2. Depin splices SP1 (red wire) and SP2 (black
wire) on MT12 wire harness. Check for open
between red and black wire to MT12.
Does open exist?
YES
Replace NGB 2 oil
pressure transducer
(TM 1-1520-238-23).
Go to paragraph 613.
NO
Go to step 3.
3. Detach P60. Check for open between P60L
and SP1 (red wire).
Does open exist?
YES
Repair open wire
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Go to srep 4.
4. Detach P672. Check for open between
P67285 and J60L.
Does open exist?
YES
Repair open wire between:
P67285 and J524A7,
P524A7 and J60L
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Refer to TM 9-1230-476-20-2 to
troubleshoot multiplex
subsystem.Refer to
TM 9-1230-476-20-2 to
troubleshoot multiplex
subsystem.
END OF TASK