TM 1-1520-238-T-4
682.12
Change 5
619.1. HOD NGB 1 READING DISPLAYS 31 C TEMPERATURE
619.1
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 1-1520-238-T-6
TM 55-1500-323-24
TM 9-1230-476-20-2
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L200 access panel and
LN6, L60 fairings open.
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
NOTE
A 32 C reading is caused by no
power to the transducer (MT15) or no
signal from the transducer to the
MRTU TYPE 1 (A63).
If all HOD temperatures are 32 C and
ENG START circuit breaker is open,
troubleshoot with Task 622.2 before
proceeding.
Entry in ( ) following pin locations is
multimeter lead orientation.
1. Detach P61. Check for open between:
P61F and P61G (red/blk),
P61J and P61H (blk/red).
Does open exist?
YES
Go to step 3.
NO
Go to step 2.
2. Check for short between:
P61F and ground,
P61H and ground.
Does short exist?
YES
Go to step 3.
NO
Go to step 4.
3. Locate open or short in the wire harness
between P61 and MT15.
Can wire harness be repaired?
YES
Repair wiring
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Replace MT15
(TM 1-1520-238-23).
Go to paragraph 613.
4. Detach P673. Check for short between:
P67387 and ground.
Does short exist?
YES
Repair shorted wire between:
P67387 and ground
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Go to step 5.
5. Reconnect P61. Check for open between:
P67386 and P67387 (blk/red).
Does open exist?
YES
Repair open wire
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Refer to TM 9-1230-476-20-2 to
troubleshoot multiplex
subsystem.
END OF TASK