TM 1-1520-238-T-4
6102
640.
ENG CUT CIRCUIT BREAKER DOES NOT STAY CLOSED
640
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68F
Aircraft Electrician
References:
TM 1-1520-238-T-6
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for short between (A76)J1b and ground.
Does short exist?
YES
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc emergency bus
pilot station)
NO
Go to step 2.
2. Identify and detach wires from (A402):
TB229T and TB229Z. Check for short
between (A402):
J21A18 and ground,
J27B2 and ground.
Does short exist?
YES
Repair shorted wire between
(A402):
J21A18 and TB229T,
J27B2 and TB229Z.
Go to paragraph 612.
NO
Go to step 3.
3. Detach P755. Check for short between P431B2
and ground.
Does short exist?
YES
Repair shorted wire between
P431B2 and P7551.
Go to paragraph 612.
NO
Refer to chapter 4 to
troubleshoot power plants.
END OF TASK