TM 1-1520-238-T-4
6106
643.
VIB MON CIRCUIT BREAKER (CB79) DOES NOT STAY CLOSED
643
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68F
Aircraft Electrician
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With VIB MON circuit breaker open. Check for
short between P128P and ground.
Does short exist?
YES
Go to step 2.
NO
Replace rotor balance signal
processor (TM 1-1520-238-23).
2. Detach P1. Check for short between P128P
and ground.
Does short exist?
YES
Repair shorted wire between:
P440B14 and P128P.
(A402):
J110 and J16B14.
Go to paragraph 612.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc essential bus 2
pilot station).
END OF TASK