TM 1-1520-238-T-5
769
714.
PRI HYD INDICATOR DOES NOT INDICATE 3000 PSI (AGPU OPERATING)
714
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Hydraulic system
leak check
completed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check EMERG HYD circuit breaker.
Is circuit breaker closed?
YES
Go to step 2.
NO
Go to paragraph 742.
2. Check for 28 VDC at P2396.
Is voltage present?
YES
Go to step 3.
NO
Go to step 4.
3. Check for open between P2397 and ground.
Does open exist?
YES
Repair open wire between
P2397 and GS430C.
Go to paragraph 710.
NO
Go to step 5.
4. Check for 28 VDC at (A76)J1m.
Is voltage present?
YES
Repair open wire between
P463m and P2396.
Go to paragraph 710.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system
(dc emergency bus pilot
station).
5. Verify AGPU pressure for 3000 psi. Check for
4.2 VDC at P265C and P265D.
Is voltage present?
YES
Replace dual hydraulic pressure
indicator (TM 1-1520-238-23).
NO
Go to step 6.
6. Check for open between:
P265C and P2399,
P265D and P2398.
Does open exist?
YES
Repair open wire.
Go to paragraph 710.
NO
Go to step 7.