TM 1-1520-238-T-5
773
717.
OIL BYP PRI HYD INDICATOR IS LIGHTED
717
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check primary hydraulic manifold pressure dirty
filter indicator.
Is indicator retracted?
YES
Go to step 2.
NO
Replace primary hydraulic
manifold pressure strainer
(TM 1-1520-238-23).
2. Check primary hydraulic manifold return dirty
filter indicator.
Is indicator retracted?
YES
Go to step 3.
NO
Replace primary hydraulic
manifold return strainer
(TM 1-1520-238-23).
3. Check for short between P1869 and ground.
Does short exist?
YES
Go to step 4.
NO
Replace pilot caution/warning
panel (TM 1-1520-238-23).
4. Detach P239. Check for short between P1869
and ground.
Does short exist?
YES
Repair shorted wire between:
P1869 and P914B5,
J914B5 and P239 SP1,
P239 SP1 and P23912,
P239 SP1 and P23914.
Go to paragraph 710.
NO
Go to step 5.
5. Check for continuity between (HP1):
J613 and J614.
Does continuity exist?
YES
Replace primary hydraulic
manifold pressure dirty filter
indicator (TM 1-1520-238-23).
NO
Go to step 6.
6. Check for continuity between (HP1):
J611 and J612.
Does continuity exist?
YES
Replace primary hydraulic
manifold return dirty filter
indicator (TM 1-1520-238-23).
NO
Go to step 7.
7. Check for short between (HP1)J614 and
chassis ground.
Does short exist?
YES
Go to step 8.
NO
Go to step 9.