TM 1-1520-238-T-5
7114
734.
ROTOR BRAKE DOES NOT RELEASE
734
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With RTR BK switch set to OFF, check RTR
BRK circuit breaker.
Is circuit breaker open?
YES
Go to paragraph 733.
NO
Go to step 2.
2. Check for 28 VDC at P23815.
Is voltage present?
YES
Go to step 5.
NO
Go to step 3.
3. Check for 28 VDC at P173Z.
Is voltage present?
YES
Go to step 4.
NO
Repair open wire between
P173Z and (A402)TB29R.
Go to paragraph 721.
4. Check for open between P173a and P23815.
Does open exist?
YES
Repair open wire.
Go to paragraph 721.
NO
Replace pilot power quadrant.
(TM 1-1520-238-23).
5. Check for open between P23814 and
GS630B.
Does open exist?
YES
Repair open wire.
Go to paragraph 721.
NO
Go to step 6.
6. Remove rotor brake off solenoid
(TM 55152023823). Check for open between
(HP2):
J115 and J5A,
J114 and J5D.
Does open exist?
YES
Replace utility hydraulic
manifold (TM 1-1520-238-23).
NO
Replace rotor brake off solenoid
(TM 1-1520-238-23).
END OF TASK